Erectonus Home Erectonus — electric prostate stimulation device

User Manual

This user manual describes the methods of application of the device both for men and women. This device is intended to be used for treatment of such conditions as chronic prostatitis, sexual dysfunction, menstrual dysfunction, chronic inflammatory processes in genitals, functional female sterility, etc.

Information contained herein may be useful for consultants and people without medical education.

Method of use are quite similar to that of Dr. Erector – predecessor of Erectonus, which some of our customers may be familiar with. However, it should be noted that Erectonus has a unique zinc coating providing endogenous electrophoresis of zinc ions, and this additional feature distinguishes it from Dr. Erector.

Description and specifications

The Erectonus is an autonomous pulse stimulator, which has a probe tube and a handle for comfortable use in rectal and vaginal areas.

The stimulator capsule consists of two hemispheric metal caps, which are put together on a dielectric adapter sleeve. The probe tube is connected to one of the caps by means of connecting branch. Inside the capsule there are three batteries and a microcircuit of square-wave generator, which produces electrical impulses on 100-400 Ohm load resistor with the following parameters:

Voltage amplitude of the impulse 3-4 V
Pulse duration 6 milliseconds
Pulse repetition period 24 milliseconds
Burst time 380 milliseconds
Burst period 3 seconds

Minimal warranted duration of persistent working – not less than 75 hours

Method of use for men

Men can use this device by rectal application only.

  1. Before use of the electrical pulse stimulator wash your hands in order to provide hygiene and to avoid the electrostatic influence on metal capsule of stimulator.
  2. Extract the LED from the package and pull its tips apart (Picture 1).

  3. Check if the stimulator is in working condition. For this purpose press the tips of LED to metal hemispheres of capsule and keep them in this position for ten seconds (Picture 2).

    When the device is capable to work the LED will blink every 3 seconds. If it does not blink, change the position of tips (put them to opposite poles) and try again. If the LED does not blink periodically in both these positions so the device is not fit to use.

  4. In order to make installation of the device easier grease the capsule of electrical pulse stimulator with vegetable oil (sunflower-seed oil, sea-buckthorn, pumpkin, cedar oil or any other). Lying on the left side bend your knees and press them to your breast, then slowly put the capsule of stimulator into rectum to a depth of 6-8 cm, so that the capsule is located at the prostate level.
  5. Stimulation starts after the contact between mucous membrane of rectum and electrodes of stimulator. In this time you can sense distinctive contractions of muscles in the rectum, perineum, pubis and along the urethra. If you do not sense such contractions it may indicate the wrong position of capsule of stimulator in the rectum relatively the level of prostate. Please correct the position of capsule until you can sense typical contractions of muscles. Also the peristalsis of large intestine may increase. Stimulator should be kept in this position (at the level of prostate) during the whole procedure (Picture 3).

  6. The duration of the procedure must be about 8-10 minutes. The treatment procedure should be carried out every day or every other day. The course of treatment includes 10-15 procedures and it may be repeated in 3 or 4 months (2 or 3 treatment courses a year).
  7. Stimulator may be used for immediate help in order to cause or improve the erection of penis. For this purpose the stimulator should be put into the rectum just before the coitus. It may be kept in the rectum at the level of prostate (on the depth of 6-8 cm) directly during the coitus, because it does not cause any negative reactions in sexual partners.
    The positive effect of erection stimulation starts in the first minutes of stimulation (Picture 4).

    After 3-5 procedures of stimulation the patient will note the improvement of penis erectile function, that will enable to make a pause in using Erectonus for 2 or 3 weeks.

  8. At the end of procedure smoothly extract the stimulator from the rectum, wash it thoroughly with the soap and hot water (Picture 5), wipe it with disinfectant (70% alcohol, or any other); then dry and put into the package.

    Attention! If the capsule of stimulator gets damp, it will continue to work and consume energy, leading to the decrease of service life.

Method of use for women

  1. Before use of the electrical pulse stimulator wash your hands in order to provide hygiene and to avoid the electrostatic influence on metal capsule of stimulator.
  2. Extract the LED from the package and pull its tips apart. Check if the stimulator is in working condition. For this purpose press the tips of LED to metal hemispheres of capsule and keep them in this position for ten seconds. When the device is capable to work the LED will blink every 3 seconds. If it does not blink, change the position of tips (put them to opposite poles) and try again. If the LED does not blink periodically in both these positions so the device is not fit to use.
  3. To make the installation of the device easier grease the capsule of electrical pulse stimulator with vaseline or vegetable oil.
  4. Woman should lie on her back and move apart her hips, and then medical assistant puts carefully and smoothly the capsule of stimulator into the vagina along its back wall to setting it in the back fornix. Woman also may do this procedure herself. After that she may strengthen her legs or lie in another comfortable position.
  5. Pulse stimulation starts just after the contact between the mucous membrane of vagina and the capsule of pulse stimulator, and it can be sensed as tingling, weak tremor and other unusual sensations. The duration of the procedure should be about 10-15 minutes. With each next procedure you may increase the duration for 5 minutes leading it to 25-30 minutes.
  6. The treatment procedure should be carried out every day or every other day. The course of treatment includes 10-15 procedures and it may be repeated in 3 or 4 months ( 2 or 3 treatment courses a year).
  7. At the end of treatment procedure smoothly extract the stimulator from vagina, wash it thoroughly with the soap and hot water, wipe it with disinfectant (6% hydrogen peroxide) two times (the second time – in fifteen minutes); then wipe dry and put into the package.

Attention! If the capsule of stimulator gets damp, it will continue to work and consume energy, leading to the decrease of service life.

One more important issue in the process of treatment is psychological readiness for this procedure, including a good mood for achievement of optimal treatment effect, and comfortable and friendly climate around the patient (family relationships, sexual relationships, etc.).

Each procedure of pulse stimulation should be carried out in favorable and comfortable situation, without any interference, jokes and sarcasm about this intimate problem. Partner’s support and love is also needed.

.